Energy Dump
New Phidget motor controllers include onboard voltage sensing that will attempt to mitigate damage caused by irregular voltage events.
Input Voltage During Operation (VDC) | Result |
---|---|
8-30 | Normal operation |
>= 42 | Energy Dump error condition. The Phidget will attempt to regulate the voltage. The Phidget will stop controlling the motor, entering a freewheel state until a full power cycle occurs. |
Please note that the voltage regulation mentioned in the table above is not intended to protect against continuous over-voltage conditions and may shorten the life of your controller. To ensure your system is properly protected against these events, a Power Guard Phidget is required.
Over Temperature
New Phidget motor controllers include onboard temperature sensing that provides thermal protection for your system. View the table below for more information.
Temperature | Result |
---|---|
< 75°C | Normal operation |
75°C to 90°C | Current Limit and Surge Current Limit scaling begins. Your current limits will scale down linearly from your set value as temperature increases, to a maximum of 40A at 90°C. |
90°C to 100°C | Current Limit and Surge Current Limit are limited to 40A. |
>= 100°C | Over Temperature condition. The Phidget will stop attempting to control the motor. It will enter a freewheel state until the Phidget is closed and reopened via software. |